VIP 3000/VIP 4000 - IP AND
RESISTIVITY ADVANCED TRANSMITTER

Features
-
3000V output voltage
-
Full microprocessor control
-
Ease-of-use
-
Standard motor generator
General
The VIP family of transmitters is
now available in either a 3000 or 4000 watt version.
Both VIP Systems are power current regulated Time Domain
and Frequency Domain electrical transmitters.
VIP 3000/VIP 4000 Major
Benefits
Light in weight and provided with a
high voltage (3000V) output, the VIP 3000/VIP 4000 are
particularly convenient for IP surveys in high
resistivity rugged areas and for deep resistivity
soundings.
Microprocessor controlled for ease
of operation and protection against misuse, all
injection parameters (current, voltages, ...) are
controlled. The VIP 3000/VIP 4000 can also be operated
through its remote control port (RS232).
The VIP 3000/VIP 4000 eight output
dipoles provide for higher productivity in the field.
Powered from a standard 220V single phase motor
generator, the VIP 3000/VIP 4000 eliminate the
maintenance and supply problems associated with custom
power sources. It also reduces the costs and problems of
shipping motor generators over long distances, namely by
plane.
High Outputs
The VIP 3000/VIP 4000 will generate
up to 3000 volts for work in high resistivity areas and
up to 5 amperes at 600 volts (VIP 3000) / 800 volts (VIP
4000) for low resistivity regions.
With its weight of only 16kg, the
VIP 3000/VIP 4000 are the lightest 3000W/4000W units on
the market.
Heavy Duty Construction
Very high quality connectors, and
heavy duty industrial components are used throughout.
The VIP3000/VIP 4000 are shock resistant and
weatherproof, for a higher reliability.
Fully Automated
The VIP 3000/VIP 4000 are designed
for ease of operation. They have a much simplified front
panel: current, dipole and frequency (in the frequency
domain) settings are the only parameters to be selected
by the operator. All the other functions, like voltage
range setting, are fully automated.
Programmable
Programming functions are also
available, either through the front panel, with a
suitable key, or from an external computer terminal.
These functions are used to select the parameters and
options that are not normally changed during a survey:
operating mode, time or frequency domain, cycle time,
frequencies, etc.
This approach reduces front panel
cluttering and drastically reduces the possibility of
operator mistake. Instrument reliability is also
increased. For example, it is not possible to switch
dipoles when transmitting. This eliminates the
possibility of burning out the selector switch or the
output circuitry.
Error Messages
Intelligent messages and warnings
are displayed in case of problem or malfunction.
Furthermore, the permanent storage of all the parameters
related to the operation of the unit make easier the
remote identification of a trouble by the manufacturer
for quicker instrument servicing.
Complete Display
A large backlighted LCD
alphanumeric display is provided for the simultaneous
indication of all output parameters. Output current,
output voltage, contact resistance and output power are
continuously displayed.
Intelligent Regulation
The VIP 3000/VIP 4000 internal
microprocessor is capable of excellent current
regulation in almost any load.
Current is operator selectable in
preprogrammed steps from 50mA to 5 amperes. Intelligent
current adjustment algorithms are always in operation.
For example, the contact resistance will occasionally be
too high for the VIP 3000/VIP 4000 to provide the
requested current setting. In such cases, the VIP
3000/VIP 4000 will display a warning message and will
set the current to the maximum value allowable under
that combination of current setting and contact
resistance. Some reserve current capacity will always be
kept to insure that the current stays constant during
the measurements, whatever the contact resistance
fluctuations.
Remote Control
The VIP 3000/VIP 4000 are provided
with a remote control port. By using radio modems, it
can be operated from a remote location.
The VIP 3000/VIP 4000 can also be
linked to an intelligent receiver such as the ELREC 6 or
the ELREC 10, or to a computer, for the automatic
recording of current settings. Finally, synchronization
with a receiver or system is also possible in both
directions (i.e. Rx to Tx or Tx to Rx).
Works With Almost Any Power
Generator
The VIP 3000/VIP 4000 IP
transmitter can be powered by almost any motor generator
providing a nominal 230V, 45-450 Hz output, single
phase, at a suitable KVA rating.
Low cost commercial generator sets,
available at local hardware or equipment rental stores
are perfectly suitable.
For related interpretation
software see RESIX IP, RESIX 2DI, and RESIX IP2DI.
Specifications
Output Power: 3000/4000VA maximum
Output Voltage: 3000 V maximum,
automatic voltage range selection
Output Current: 5 amperes maximum,
current regulated
Current accuracy: better than 1%
Current stability: 0.1%
Dipoles: 8, selected by push button
Output Connectors: connectors
accept bare wire or plug of up to 4mm. diameter.
Tune Domain Waveforms: On+, off,
on-, off, (on = off) preprogrammed cycle. Automatic
circuit opening in off time. Preprogrammed on times from
0.5 to 8 seconds by factor of two. Other cycles
programmable by user.
Frequency Domain Waveforms: Square
wave, Preprogrammed frequencies from 0.0625 Hz to 4 Hz
by factors of 2. Alternate or simultaneous transmission
of any two frequencies. Other frequencies programmable
by user.
Time and Frequency Stability:
0.01%, 1 PPB optional
Display: Alphanumeric liquid
crystal display. Simultaneous display of output current,
output voltage, contact resistance, and output power.
Protection: Short circuit at 20
ohms, Open loop at 60000 ohms, Thermal, Input
overvoltage and undervoltage.
Remote Control: Full duplex
RS-232A, 300-19200 bauds. Direct wire sync for on-time
and polarity.
Miscellaneous
Dimensions (h w d): 41 x 32 x 24
cm.
Weight: 16 kg
Power Source: 175 to 270 VAC,
45-450 Hz, single phase Motor Generator
Operating Temperature: -40 to +50
degrees Celsius.
Standard Components
VIP 3000 or VIP 4000 Console,
Programming Key, RS-232 Interface Cable, Motor Generator
Cable, Operations Manual and Shipping Case.
|