IX1D - 1D Inversion Software

Data Entry Dialog Box
IX1D is a 1-D Direct Current (DC) resistivity and
Induced Polarization (IP) inversion program with the
following features:
-
Supports Most DC resistivity
arrays, including: Wenner, Schlumberger
Dipole-dipole Pole-dipole and Pole-pole arrays.
-
Supports Resistivity only or
Resistivity with IP measurements in terms of PFE,
Chargeability in msec or Phase in mrad.
-
IX1D has the capability to read
in a resistivity well log from a flat ASCII file and
the user can interactively reduce the log to several
discreet layers by fitting straight line segments to
the cumulative conductance in the log. The resulting
model can be copies to the model in the current data
set for further modeling.
Features include:
-
Creation of data by spreadsheet
entry
-
Import of data or models from
flat ASCII files
-
Models are entered from the
keyboard as either Depth models or Layer Thickness
-
Layer boundary elevations are
shown and calculated relative to surface
elevations.
-
The Model Entry dialog box
allows for dynamic column and row manipulations to
make model entry more convenient.
-
Fix Flags allows the user to
fix parameters for the inversion calculations.
Either the layer thickness (or depth) and/or the
resistivity can be fixed in the inversion process.
-
Forward and inverse model
calculations can be carried out using buttons on the
model entry dialog. Models can be inverted using
either the layer depth or layer thickness.
-
Graphics are presented as the
Sounding data on the left hand side with the model
on the right hand side. Interactive property sheets
allows for user configuration of displayed data. For
DC and IP data, the model can be displayed on the
same axes as the data.
-
Menu commands and toolbar
buttons are available for estimating a layered model
(DC and IP data only), estimating a smooth model or
analyzing equivalence of the layered model.
-
Smooth models are generated by
starting with as many layers as there are data
points. Thicknesses are automatically generated from
the spacing or frequency data and the model begins
with a homogeneous earth (all layers set to the
average resistivity found in the data). Inversion
can be Ridge Regression or Occam's inversion.
-
The display can be set to show
the layered model, smooth model, equivalence
analysis or any combination of these three. The
model(s) can also be shown on the same graph as the
data, in which case the spacing axis doubles as a
depth axis.
-
The model and data plots can be
zoomed by dragging the mouse across the display with
the left button depressed. This feature can be
switched on and off by clicking on the Zoom menu
command in the View menu or by clicking on the Zoom
tool bar icon.
-
Axes labels as well as axis
sizes can be edited under View Properties. Grid
lines, including major and minor, for the Data and
Model axes can be switched on and off under the View
Grid menu sub choices. Axes can be auto-scaled from
the model and data by selecting the View Unzoom menu
command.
-
Data, Layered models and Smooth
models can be exported to ASCII files.
-
Graphics can be exported as DXF,
CGM or WMF file formats.
-
Tool bar buttons are provided
for the most-used menu commands, including New
Sounding or Model, Open and Import data, Save,
Print, Edit Data or Model, Zoom status, Unzoom,
model display selection, Forward, Inverse and
Equivalence Analysis calculations, and Estimation of
Layered or Smooth models.

Model entry Dialog Box

Axes Label Properties

Resistivity Well log show with layered model
interpretation

Default Graphics Screen
|